Subscribe to Windows IT Pro
July 17, 2001 12:00 AM

Netlogon Error Message

Windows IT Pro
InstantDoc ID #21440
Rating: (6)

We recently enhanced our network with switched Ethernet technology. All the servers and workstations in the network run Windows NT 4.0 with the latest service pack. Although this enhancement provided a faster network, it presented a problem that hadn't previously occurred.

When booted, some of the faster workstations in the network (Pentium III processor—class systems) reported a Netlogon error (event ID 5719—No Windows NT Domain Controller is available for domain) in the System event log. Sometimes, if the user logged off and logged on again without restarting the computer, all services would start without problems. None of the slower computers produced this error message.

After trying workarounds such as upgrading the NIC software, I hadn't found a solution. Finally, I came across the Microsoft article "Increase Domain Logon Timeout over Network" (http://support.microsoft.com/support/kb/articles/q163/2/04.asp), which provided a solution: Use a registry editor to add the ExpectedDialupDelay parameter of type REG_DWORD to the HKEY_LOCAL_MACHINE\SYSTEM\ CurrentControlSet\Services\Netlogon\Parameters subkey. This value has a range of 0 to 600 seconds. To find the right timeout value, I experimented a bit and came up with a value for my network of from 4 to 8 seconds. My theory is that this logon delay is necessary to let the switches build entries in their routing tables as soon as the client starts.

Related Content:

ARTICLE TOOLS

Comments
  • JEFF
    7 years ago
    Dec 27, 2005

    how about something a little more recent

  • Anonymous User
    7 years ago
    Mar 24, 2005

    I did the above changes in my clinet machine(WinXP). Still I am not able to domain logon. Sometime I can LOGON to domain(not cached), but sometime I can not. I put delay=600, but still my machine is not waiting for 10 minutes ?

    Thanks in advance,
    Naresh

  • bob
    9 years ago
    May 04, 2003

    Just enable port fast on the switch port where these machines are connected. Actually disable spanning tree on the end station ports.

  • ROBERT
    11 years ago
    Aug 02, 2001

    Anyone know how to implement this fix on Windows 9x ?

You must log on before posting a comment.

Are you a new visitor? Register Here

advertisement

advertisement

Windows is a trademark of the Microsoft group of companies. Windows IT Pro is used by Penton Media Inc. under license from owner.